INNO-S Multimode Microplate Reader (Absorbance, Luminescence & Fluorescence):


The LTEK INNO-S is a versatile multimode microplate reader designed for accurate absorbance, luminescence, and fluorescence measurements. It features a monochromator-based optical system covering a wavelength range of 200 to 999 nm for absorbance, 250 to 750 nm for luminescence, and 350 to 750 nm for fluorescence. The device supports various assay types, including endpoint, kinetic, spectral scanning, and area scanning, across 6 to 384 well plates. Equipped with a xenon flash lamp for absorbance, a high-power LED for fluorescence, and a low-noise photomultiplier tube (PMT) for luminescence, the INNO-S ensures high sensitivity and precision. Additional features include incubation up to 50°C, linear and orbital shaking with adjustable speeds, dual reagent injectors, and the INNO-X software for robust data analysis with multiple regression options

Compare
General
Detection modes UV-Vis Absorbance
Fluorescence intensity
Luminescence
TRF (Time-resolved fluorescence)
Read methods End point
Kinetic
Spectral scanning
Well-area scanning
Microplate types 6- to 384-well plates
Others labware supported NANO-VC (Microvolume Plate)
INNO-QM (Quality Check Plate)
Temperature control Up to 50 °C ± 0.2°c at 37°c
Shaking Linear & Orbital & Double Orbital with 4 different speeds
Software INNO-XTM (Basic software) & INNO-XSTM (21 CFR part 11 Compliance Software) (Optional)
Certifications IVD
CE Marked
RoHS
ISO 9001 / ISO 13485 / ISO 14001
21 CFR Part 11 Compliance Software
Absorbance
Light source Xenon flash lamp
Detector Photodiode
Wavelength selection Monochromator
Wavelength range 200−999 nm, 1nm increments
Dynamic range 0−4.0 OD
Resolution 0.0001 OD
Pathlength correction Yes
Wavelength accuracy ±2 nm
Wavelength repeatability ±0.2 nm
OD accuracy 0 to 2 OD: ± 1% ± 0.010 OD
OD linearity <1% from 0 to 3.0 OD
Fluorescence Intensity (Filter-based Fluorescence Intensity)
Light source High Power LED
Detector PMT
Wavelength selection Filters
Wavelength range 350~750 nm (Options 850nm)
Dynamic range >6 decades
Sensitivity Top and Bottom : Fluorescein 5pM
(1 fmol/well, 96-well plate)
Luminescence
Wavelength range 200~700 nm (Options 850nm)
Wavelength selection Filters
Detection system Low noise PMT
Sensitivity 10 amol ATP (filter)
Dynamic range >7 decades
Peak wavelength 410 nm
TRF (Time-Resolved Fluorescence)
Light source High Power LED
Detector Filters
Wavelength selection PMT
Physical Characteristics
Connectivity 1 USB, 1 RS232 for external PC control
Power 100-240 Volts AC. 50/60 Hz
Dimensions 408W x 390L x 290H
Weight 18.2 kg
Applicable optional products
Reagent Injector (INNO-D)
  • 2 Syringe pumps
  • 5~1,000μ → 15~1,000μ
  • Minimum prime Vol. 1.1mL, 100μL with back flush
Microvolume Plate (NANO-VC)
  • Nucleic acid and protein quantification with DNA/RNA, Lysozyme, dsDNA, ssDNA, Etc.
  • 2-2.5μL sample capacity with 24 wells
  • 2.5ml cuvette holder
Quality Check Plate (INNO-Q)
  • Absorbance linearity, accuracy, and alignment QC
INNO-S Product line Configurations
The user can select TWO filter sets by default when purchasing the INNO-S(F) model
INNO-S INNO-SA INNO-SF
Absorbance
Fluorescence
Luminescence
TRF
Shaking
Incubation
Dual Reagent injector
Category: Brand: