SD-33/SD-33C Vacuum Centrifugal Concentrator With Cold Trap


Experience precision and efficiency with this advanced centrifugation concentrator, featuring a high-definition LCD touch screen that displays speed, temperature, vacuum, and runtime in real time. Its automatic vacuum control system—with a range of 0.1–1000 mbar and a delayed start function—ensures optimal conditions while preventing sample mixing. The device is programmable with customizable temperature and pressure settings, allowing storage of up to 36 programs, and supports tool-free rotor replacement for enhanced versatility. Built with a maintenance-free magnetic drive and robust safety features such as an inductive self-suction door lock, it seamlessly integrates into freeze-drying systems for reliable laboratory performance.

Compare

Key features:

1. High-definition LCD touch screen, simultaneously displaying operational parameters: speed, temperature, vacuum, and running time.
2. Delayed start: after reaching a fixed speed, Start the vacuum pump to effectively prevent sample mixing.
3. Fully automatic vacuum control system, vacuum setting range0.1~1000mbar, Control accuracy0.1mbar.
4. 1.5/2ml Rotor stacking for simultaneous use; rotor replacement without tools.
5. Programmable with temperature and pressure settings; capable of storing 36 programs
6. Compatible with various rotor heads; transparent glass window for easy observation.
7. Magnetic drive: maintenance-free, non-contact drive, fully sealed.
8. Safety in use: inductive electric self-suction door lock ensures the centrifugal concentrator can only start when the door cover is fully closed and locked.
9. Can be used in conjunction with freeze-drying systems

SD-33/SD-33C Vacuum Centrifugal Concentrator

Ambient temperature type/Refrigerated type

Technical Parameter

Temperature range Room Temperature~+80℃ -10℃~+80℃
Temperature Accuracy 士1℃
Max.Speed 2500rpm
Max.Capacity 12x100ml
Timer 0~99h59min
Vacuum control range 0.1~1000mbar
Main unit withstands vacuum levels 0.01mbar
Noise ≤58dBA ≤68dBA
Voltage 0.7kw 0.9kw
Power supply 220v,50Hz
Dimension(L×W×Hmm) 440*536*304mm 540*653*420mm

Adapter Rotor

Rotor Type Rotor Volume Rotor Type Rotor Volume
Angle Rotor 42×1.5/2ml Angle Rotor 8×50ml
Angle Rotor 108×1.5/2ml Angle Rotor 6×100ml
Angle Rotor 48×5ml Angle Rotor 16*20ml Sample vial
Angle Rotor 30×10ml Angle Rotor 16*5ml+8*4ml+8*3ml
Angle Rotor 24×15ml Microplate Rotor 2×96well

 

Cold trap(The cold trap is optional and can be customized to meet the customer’s needs)

The evaporation rate is influenced not only by the energyinputbut also by the pumping speed of the vacuum pump. The mainfactor affecting the efficiency of the vacuum pump is the largeevaporative surface area of the sample, rather than thesample quantity or volume. To reduce evaporation time, werecommend using a cold trap in conjunction with centrifugalconcentration.This not only helps in condensing water vaporbut also increases the vapor density of organic solventsmakingit easierforcondensation to occur.

Category: Brand: