The POClia 8 Immunoassay Analyzer is a compact, high-performance chemiluminescent immunoassay (CLIA) system designed for rapid and accurate diagnostics in various clinical settings. Utilizing advanced CLEIA technology combined with magnetic particle separation, it delivers precise results across a broad spectrum of tests, including cardiac markers, tumor markers, inflammatory indicators, thyroid hormones, and diabetes-related biomarkers.
With an 8-channel parallel detection capability, the POClia 8 achieves a throughput of up to 32 tests per hour, providing the first results in just 15 minutes. It accommodates sample types such as whole blood, serum, plasma, and urine, enhancing its versatility in point-of-care testing (POCT) environments.
The analyzer features a user-friendly LCD touchscreen interface, built-in printer, and computer, streamlining operations and data management. Its compact design (530mm x 626mm x 426mm) and lightweight structure (30kg) make it suitable for primary hospitals, clinics, and laboratories with limited space. The system supports 24-hour standby operation, ensuring readiness for urgent testing needs.
The POClia 8’s extensive test menu includes critical parameters like NT-proBNP, D-Dimer, hs-cTnI, IL-6, CRP, TSH, HbA1c, AFP, CEA, and 25-OH-Vitamin D, among others. Its high sampling accuracy (CV ≤ 5%) and low sample carry-over (< 0.1 ppm) ensure reliable and reproducible results.
Ideal for emergency departments, intensive care units, and clinical laboratories, the POClia 8 Immunoassay Analyzer offers a robust solution for rapid, on-site diagnostic testing, enhancing patient care through timely and accurate results.
Key Features:
-
Multiplex Testing
-
Capable of running up to 8 different tests simultaneously on a single sample.
-
-
High Sensitivity & Specificity
-
Uses advanced chemiluminescence immunoassay (CLIA) technology for accurate detection of low-concentration biomarkers.
-
-
Rapid Results
-
Delivers test results typically within 15 minutes, ideal for urgent diagnostic needs.
-
-
User-Friendly Interface
-
Equipped with a touchscreen and intuitive software for easy operation, even by non-laboratory staff.
-
-
Compact & Portable Design
-
Small footprint, suitable for point-of-care settings like clinics, emergency rooms, or mobile labs.
-
-
Minimal Sample Volume
-
Requires only a small amount of blood (typically a finger-prick sample).
-
-
Automated Operation
-
Fully automated workflow from sample loading to result output; no manual intervention needed.
-
-
Data Connectivity
-
Supports USB, LAN, and LIS/HIS integration for efficient data management and reporting.
-
-
Built-in Quality Control
-
Integrated quality control functions ensure test accuracy and reliability.
-
Applications:
-
Cardiovascular Disease Monitoring
-
Troponin, BNP, D-dimer, etc.
-
-
Hormone Testing
-
TSH, LH, FSH, Progesterone, Testosterone.
-
-
Diabetes Management
-
Insulin and C-peptide levels.
-
-
Infectious Disease Detection
-
COVID-19 antibody tests, Hepatitis markers.
-
-
Inflammation & Sepsis
-
CRP, PCT (Procalcitonin).
-
-
Fertility and Pregnancy
-
β-hCG and related markers.
-
-
Thyroid Function Tests
-
Tumor Markers
-
PSA, AFP, CA125, CA199.
-
Specifications
Instrument type | Automatic Chemiluminescent Immunoassay Analyzer |
Model | POClia 8 |
Dimensions | 530(W)*626(D)*426(H)nm |
Weight | 30kg |
Test batch | 8-channel parallel detection |
Testing time | Depending on the reagent item |
Sample | Whole blood/Serum/Plasma/Urine (depends on reagent type) |
Principle | CLEIA and Magnetic particle separation technology |
Sampling accuracy | CV<1%,100ul for example |
Temp control of the reaction area | 42 ± 0.5℃ Fluctuation:≤1.0℃ |
Spectra module of the test module | 300nm ~ 650nm |
Linear correlation | Within a concentration range of not less than 2 orders of magnitude, the linear correlation coefficient (r) ≥ 0.99 |
Inter-batch repeatability | (CV,%)≤8% |
Stability | Results CV at 4 hour, 8 hour with the initial time when machine is steady is ± 10% |
Data storage | Patient date: >100000 |
QC Date | >100000 |
Calibration Date | >100000 |
Power supply | 100-240 VAC , 50Hz , 200VA |
Printer | Built-in |
Computer | Built-in |
Screen | LCD touch-screen |
24h operation (standby) | Recommend |