PINS3-CW-G2 Portable Isotopic Neutron Spectroscopy

ORTEC

PINS Overview
The Portable Isotopic Nuclear Spectroscopy (PINS) Chemical Identification System identifies dangerous compounds and mixtures non-destructively. The test object need not be opened or touched, providing significant safety benefits. As shown, PINS probes a test object with neutrons that excite the atomic nuclei within, causing the excited nuclei to produce gamma rays. The energy intensity pattern or spectrum of these gamma rays is unique for each chemical element, and by analyzing the gamma-ray spectrum, the PINS software identifies the chemical elements inside the test object and determines if the object contains a chemical warfare agent, a fill (such as sand), or a smoke generating chemical.

Compare

PINS3-CW-G2 combines the latest chemical analysis identification technology with the industry-leading ORTEC trans-SPEC-N high purity germanium platform.

The PINS3-CW-G2 eliminates the need for liquid nitrogen and a Californium-252 neutron source, providing ease of deployment in OCONUS missions. It offers built-in automatic ID of chemicals – all in a rugged design for field deployment.

Along with the addition of the trans-SPEC-N, the PINS3-CW-G2 also includes the additional capability and features such as:

  • No liquid nitrogen is required.
  • Uses a mechanically cooled, field deployable gamma spectrometer (ORTEC trans-SPEC-N).
  • No Californium-252 source is required.
  • Auto analysis of chemicals.
  • Uses a small, portable Neutron Generator that saves weight, power, and space.
  • Ruggedized laptop with latest PINS3 Chemical Analysis and Identification software.
  • 12 hour runtime with external rechargeable batteries.
  • Lightweight carbon fiber measurement stand.
  • USB and Power cables.
  • Safety kit.
  • Hardened wheeled transport cases.

Click the links below to download:

SKU: OSR0019 Category:
brands

ORTEC

Gamma-Ray HPGe Spectrometer

Model ORTEC trans-SPEC-N
Relative Efficiency >50% typical (ANSI/IEEE 325-1996)
Energy Resolution <1600 eV @ 122 keV and ≤2.5 keV @ 1332 keV (FWHM Warranted at optimum settings and detector type)
Multichannel Analyzer (MCA) Built in digital signal processing MCA
MCA Channels Up to 16k
Dimensions 15.5 in. L x 6.55 in. W x 13.75 in. H (39.4 cm L x 16.3 cm W x 34.9 cm H)
Weight 24.4 lb. (11.1 kg)
Input Power 10–17 V DC @ 30 Watt
Internal Battery Life >3 hours @ 77°F (25°C) for a cold detector
External Battery Extends operating time to 12 hours @ 77°F (25°C) for a cold detector
Initial Cooldown Time <10 hours @ 77°F (25°C)
Maintenance Periodic detector annealing is recommended as part of a routine maintenance program for any HPGe detector operating in a high neutron environment. The scheduling of this maintenance will be dependent on the utilization and intensity of the high energy neutron source.


Laptop Computer

Model Panasonic Toughbook CF
Operating System Microsoft Windows 7 or Windows 10
Hard Disk Drive Capacity 320 GB
Battery Operation Time 12.5 hours
Charging Time 4.5 hours
Dimensions 11.9 in. x 11.5 in. x 2.9 in. (30.2 cm x 29.2 cm x 7.3 cm)
Weight 8.2 lb. (3.7 kg)


Neutron Generator Source

Model miniGEM
Neutron Yield, Nominal 6E+06 n/s
Pulse Range 0.5 to 20 kHz
Duty Cycle 5% to 90%, continuous
Mean Neutron Energy 2.5 MeV
External Battery Extends operating time to 12 hours @ 77ºF (25ºC)
Control Interface RS-232 or Ethernet (UDPv4)
Safety Features Key lock, emergency On/Off, automatic pressure interlock switch, flashing warning light
Pressurized Gas Shipping Permit DOT SPECIAL PERMIT 14690, allows the unit to ship fully pressurized. A copy of this special permit may be obtained at https://cms7.phmsa.dot.gov/approvals-and-permits/hazmat/file-serve/offer/SP14690.pdf/offerserver/SP14690
Total Weight 16 pounds (7.3 kg)
Power Consumption Less than 75 watts typical
Control Module Details Open source text and GUI
Maximum Accelerator Voltage 130 kV
Typical Tube Lifetime 1500 hours @3E+08, 4500 hours @1E+08
Outputs Source, Delay-1, Delay-2, Delay-3, Controls
Dimensions 4.25 x 8 x 10 inches
Operating Range 20 to 70 µA, 60 to 130 kV
Input Power 24 V DC ±10%
Operating Temperature –10 to +50°C
Minimum Pulse Width 5 µs

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “PINS3-CW-G2 Portable Isotopic Neutron Spectroscopy”